The Dolby DP564 is the multichannel audio reference decoder for DTV broadcast, postproduction, and DVD-authoring applications.
Critical monitoring of your signal is essential to ensure that the highest quality audio reaches your listeners at home. As our reference decoder, the Dolby® DP564 is the ideal monitoring tool for all quality-control applications. Using the DP564, you can decode and monitor programs with Dolby Digital, Dolby Digital Surround EX™, Dolby Pro Logic® and Pro Logic II, as well as regular two-channel PCM soundtracks.
Control Flexibility
The DP564 provides easy selection and monitoring of Dolby Digital's unique downmixing capabilities, listening modes, and compression modes. This gives content producers and providers an accurate way to verify how material originally produced and transmitted in 5.1 will sound when played back through Dolby Pro Logic or Pro Logic II, two-channel stereo, or mono home systems. Built-in Dolby Headphone processing, with a dedicated volume control, allows monitoring surround sound over standard headphones. The DP564 provides a comprehensive set of functions such as test noise, speaker trims and delays, bass redirection, mutes, and solos for the configuration and control of multichannel monitoring environments.
Inputs and Outputs
There are three digital inputs (one a Toslink™ optical) and an Ethernet port for RTP streaming Dolby Digital audio. A linear timecode (LTC) output allows DVD facilities to check A/V sync between audio encoded in Dolby Digital and uncompressed video. Front- and rear-panel serial interfaces, along with the Ethernet port, facilitate software remote control (supplied) and software updates via a PC. A rear-panel GPI/O port also offers remote control from the Dolby Cat. No. 549 GPI/O controller or other external source.
The ideal companion encoder units are the Dolby DP569 for creating Dolby Digital material, and the Dolby DP563 for encoding into Dolby Pro Logic II and Dolby Pro Logic.
ENLARGE
DP564 Front Panel
Multifunction Display
For status indication and setup operations
Keypad
Access to all Dolby downmix, decode, listening, compression modes and user-assignable presets; input and monitoring selection
Volume Controls
Master and headphone levels
Headphone Output
6.35 mm (1/4-inch) standard stereo headphone jack, user-selectable: Dolby Headphone or stereo modes, +7 dBu maximum output into 50Ω nominal
RS-232 Serial Remote Port
8-pin female mini-DIN connector for remote control and software upgrades
DP564 Rear Panel
Digital Audio Inputs
Three total: two BNC female connectors, unbalanced, 75Ω, signal levels per AES-3ID-1995 (SMPTE 276M); one fiber-optic via Toslink connector
AES Reference Input
BNC female with loop-through, unbalanced, 75Ω, signal levels per AES3-ID-1995 (SMPTE 276M), external 75Ω termination required
Digital Audio Outputs
Four BNC female connectors, unbalanced, 75Ω, signal levels per AES-3ID-1995 (SMPTE 276M)
Analog Audio Outputs
0 dBFS = +24 dBu; balanced floating; eight 3-pin XLR male connectors, 24-bit DAC
Linear Timecode Output Port
One SMPTE 12M-1995, BNC female, unbalanced, nominal output signal 1 Vp–p, output impedance 50Ω
RS-485 Serial Remote Control Input/Output Port
9-pin female D-connector for remote control and software upgrades
General Purpose Input/Output Port
37-pin female D-connector, TTL compatible, may be configured to be level or edge sensitive using either polarity; supports Dolby Cat. No. 549 GPI/O controller
Ethernet Port
RJ-45 female connector, 10/100 Base-T with auto-detection
Audio Coding Algorithms
Dolby Digital, Dolby Digital Surround EX, Dolby Pro Logic II, Dolby Pro Logic, and Dolby Headphone
Downmix Modes
Lt/Rt, Stereo, Mono
Listening Modes
Full, 3 Stereo, Phantom
Compression Modes
Line, RF, and Custom mode with adjustable parameters
Audio Input Sampling Rates
32, 44.1, 48, 88.2, and 96 kHz
Audio Output Sampling Rates
32, 44.1, and 48 kHz
Frequency Response
Digital outputs: 20 Hz to 20 kHz, ±0.01 dB Analog outputs: 20 Hz to 20 kHz, ±0.5 dB
Distortion
<0.02%, 20 Hz to 10 kHz
Dynamic Range
>106 dB
Channel Trim Level Adjust
+6 to –20 dB in 0.125 dB steps
Crosstalk
100 dB at 1 kHz
Test Noise
Auto: Sequences wideband or band-limited pink noise through enabled channels at 2-second intervals
Manual: Feeds continuous noise to selected channel when unit is in trim level mode
Power Requirements
90–264 VAC, 50–60 Hz, auto-sensing, 40 W maximum; designed to operate from a centrally switched power source
Dimensions and Weight
2-U rackmount: 88 × 483 × 376 mm (3.5 × 19 × 14.8 inches)
Net: 4 kg (8.5 lb)
Environmental Conditions
Operating: 0°C–50°C (32°F–122°F), natural convection cooling, 0%–98% relative humidity (noncondensing)
Nonoperating: –20°C to +70°C (–4°F to +158°F)
Regulatory Notices
North America: This unit complies with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules and Industry Canada ICES-003 Class A requirements. It is UL listed for the US and Canada.
Europe: This unit complies with the requirements of Low Voltage Directive 73/23/EEC and EMC Directive 89/336/EEC and carries the CE marking accordingly.
DP564
Product Manuals
Quick Start Guide
Technical Papers
Other
MSRP: $4,600
FIND A DEALER
DOCUMENT LIBRARY